How much insulation do I need?
Pick your climate zone and where the insulation goes; the calculator shows the R-value ENERGY STAR recommends. Then enter the bags per 1,000 sq ft from the bag’s coverage chart.
Last reviewed November 28, 2026 · How we check the numbers
Result
- Bags to buy
- 19
- ENERGY STAR for zone 3, attic with 3–4 in already there
- R-38
- Blown-in fiberglass thickness for R-38
- about 14.1–17.3 in
- Area
- 1,000 sq ft
An estimate for buying materials, not a substitute for plans.
Link copied
Hey, don’t lose us! We’ve got 23 calculators for concrete, gravel, fences, roofs, floors and more. Add us to your home screen, buddy — next time it’s one tap, no searching.
- Tap Share in the browser bar (in Safari it may be under ⋯).
- Scroll down and tap Add to Home Screen.
- Tap Add.
How it is calculated
- Target R-value: from the ENERGY STAR table for your zone, or your own.
- Thickness: R-value ÷ R per inch of the material (DOE ranges, so the result is a range).
- Bags: area ÷ 1,000 × bags per 1,000 sq ft; packages: area ÷ square feet per package, rounded up.
| Zone | Attic, no insulation | Attic with 3–4 in | Floor |
|---|---|---|---|
| 1 | R-30 | R-25 | R-13 |
| 2 | R-49 | R-38 | R-13 |
| 3 | R-49 | R-38 | R-19 |
| 4A/4B | R-60 | R-49 | R-19 |
| 4C | R-60 | R-49 | R-30 |
| 5 | R-60 | R-49 | R-30 |
| 6 | R-60 | R-49 | R-30 |
| 7 | R-60 | R-49 | R-38 |
| 8 | R-60 | R-49 | R-38 |
“Attic with 3–4 in” is how much to add on top. Zone 1 is south Florida and Hawaii, zone 7–8 northern Minnesota and Alaska — the ENERGY STAR page has a map.
Mistakes that give a wrong number
- Using the R per inch instead of the bag chart. Blown-in products differ. The bag’s coverage chart gives the bags per 1,000 sq ft and the thickness for each R-value — use it for the count.
- Ignoring the existing insulation. If there are already 3–4 in, ENERGY STAR’s “add” values are lower. Choose “Attic with 3–4 in already there”.
- Compressing batts. A batt squeezed into a shallower cavity loses R-value. Pick batts made for the cavity depth.
Numbers used and where they come from
- Recommended R-values: by climate zone for uninsulated attics, attics with 3–4 in of existing insulation and floors. Source: ENERGY STAR — Recommended Home Insulation R-Values by climate zone (2021 IECC).
- R per inch: blown fiberglass 2.2–2.7, cellulose 2.9–3.4, fiberglass batts 2.9–3.8, mineral wool 3.7, open-cell foam 3.5–3.8. DOE gives closed-cell foam as 7–9 in one guide and up to 6.5 in others; the calculator uses 6–7. Source: U.S. DOE Building America — Insulation guide, Table 3.2: R-value per inch by material.
- Blown-in example: Owens Corning AttiCat, 27.5 lb bag: R-38 takes 19 bags per 1,000 sq ft at 13.5 in, and settling is negligible. Source: Owens Corning — AttiCat install card (27.5 lb bag): R-38 = 19 bags per 1,000 sq ft, 13.5 in thick.
- Batt example: Owens Corning PINK Next Gen R-13 kraft-faced, 15 × 93 in: 13 pieces, 125.94 sq ft per package. Source: Owens Corning — PINK Next Gen Fiberglas fact sheet: R-13 kraft 15 × 93 in, 125.94 sq ft per package.
Manufacturer figures apply to the products named. Other brands differ — check the bag, can or data sheet of the product you buy.
Worked example
A 40 × 25 ft attic in zone 3 with 3–4 in of old insulation: ENERGY STAR recommends adding R-38. In blown fiberglass that is about 14–17 in by the DOE range (AttiCat’s own chart says 13.5 in). At 19 bags per 1,000 sq ft: 19 bags.
Tips
- Seal air leaks around attic hatches, plumbing and wiring before adding insulation.
- Keep insulation away from recessed lights not rated for contact (non-IC) and from chimney flues.
- Home centers often lend or rent the blowing machine when you buy blown-in insulation — ask at the store.
Frequently asked questions
How much insulation do I need in my attic?
R-49 to R-60 for an uninsulated attic in most of the US (zones 2–8), R-30 in zone 1, per ENERGY STAR.
How thick is R-38 blown-in insulation?
About 14–17 in of blown fiberglass by DOE ranges, about 11–13 in of cellulose. Owens Corning AttiCat reaches R-38 at 13.5 in.
How many bags of blown-in insulation for 1,000 sq ft?
It depends on the product and R-value. For Owens Corning AttiCat, R-38 takes 19 bags.
Related calculators
- Roofing calculator — Shingle bundles and squares by roof pitch
- Drywall calculator — Sheets of 4 × 8, 4 × 10 or 4 × 12 drywall
- Stair calculator — Risers, treads and stringer length to code
- Board foot calculator — Board feet and price of lumber
Sources
- ENERGY STAR — Recommended Home Insulation R-Values by climate zone (2021 IECC)
- U.S. DOE Building America — Insulation guide, Table 3.2: R-value per inch by material
- Owens Corning — AttiCat install card (27.5 lb bag): R-38 = 19 bags per 1,000 sq ft, 13.5 in thick
- Owens Corning — PINK Next Gen Fiberglas fact sheet: R-13 kraft 15 × 93 in, 125.94 sq ft per package